3 thoughts on “Jaya jyothi cement coal Mill bag filter fire”
R n sharma
Do not allow bag filter temp not more then75 C.purg inert or Co2 gas when mill is stopped for a longer period.specially when usage of high volatile coal. In case of pet coke there is rare possibility of fire.
Do not allow bag filter temp not more then75 C.purg inert or Co2 gas when mill is stopped for a longer period.specially when usage of high volatile coal.
In case of pet coke there is rare possibility of fire.
Get well soon
http://www.kamaser.com
zafrinengineeringwork@gmail.com
ZAFRINENGINEERIG
PERUMUGHAM PO
YI FEROKE
CALICAT
9746651399